UL 3656

UL 3656

For general commercial electronic, electrical, and equipment instruments’ internal wiring, suitable for applications where the ambient temperature does not exceed 150 °C.

Product Description

Insulation:XLPE
Rated temperature:-40℃ to +150 ℃
Rated voltage:300V
Conductors:40AWG-10AWG
Standards:UL758,UL1581
Flame compliant:UL CSA FT2,UL VW-1~ CSA FT1
Certificate:ROHs2.0, REACH

线规

AWG

结构(N/mm)

CONSTRUCTION

线径(mm)

DIA

绝缘厚度(mm)

AVG. THICK

完成外径(mm)

OVER DTAMEREDR

导体电阻(Ω/km20℃)

COND. RESISTANCE
18 34/0.18 1.18 0.21 1.70  ≤23.2
20 21/0.18 0.96 0.21 1.50  ≤36.7
22 17/0.16  0.76 0.21 1.28 ≤59.4
24 11/0.16 0.61 0.21 1.13 ≤94.2
24 7/0.2 0.61 0.21 1.13 ≤94.2
26 7/0.16 0.49 0.21 1.00 ≤150
26 11/0.127 0.49 0.21 1.00 ≤150
28 7/0.127 0.39 0.21 0.90 ≤239
30 7/0.1 0.31 0.21 0.80 ≤381
32 7/0.08 0.24  0.21 0.75 ≤582